10 exam-style questions with answers and explanations, straight from our 1,030-question bank. Tap an answer to check yourself. When you're ready, take the scored version in the free practice test.
Rainwater stains the siding immediately below the lower end of a roof-to-wall intersection. Individual step-flashing pieces are visible along the slope, and the gutter and downspout are clear. At the bottom of the intersection, runoff follows the wall instead of turning into the gutter. Which detail most directly accounts for this pattern?
Show answer & explanation
Correct answer: C - Missing kickout flashing at the lower end of the sidewall
Question 2
An older two-wire branch circuit supplies a GFCI receptacle labeled 'No Equipment Ground.' Its built-in TEST button interrupts power to a plugged-in lamp, and RESET restores power. A three-light tester indicates an open ground, but pressing that tester's GFCI button does not trip the receptacle. How should the conflicting test results be interpreted?
Show answer & explanation
Correct answer: A - The external tester lacks the equipment-ground path needed for its test; the built-in test did interrupt power.
Question 3
During a vaulted-ceiling remodel, the ceiling joists that tied opposing rafter feet together were removed. The rafters still meet at a nonstructural ridge board, and short horizontal ties remain near the ridge. No structural ridge beam or alternative engineered restraint was installed. Which force were the removed low ties primarily intended to resist?
Show answer & explanation
Correct answer: D - Outward thrust at the exterior walls under roof gravity loads
Question 4
On a damp 36°F morning, an air-source heat pump is heating normally when its outdoor fan pauses. A brief cloud of white vapor rises as frost clears from the outdoor coil. Within several minutes, the fan restarts and normal heating resumes. There is no burning odor or abnormal noise. Classify the observed operating sequence.
Show answer & explanation
Correct answer: B - Normal defrost; this sequence does not justify shutting the system down.
Question 5
A kitchen sink drains through an S-shaped trap whose outlet turns downward through the floor without a vent connection. The sink empties rapidly, then gurgles. The accessible joints stay dry. Adding a little water eliminates the drain odor, but the odor returns immediately after the next full sink drains. What best explains the odor's repeated return?
Show answer & explanation
Correct answer: B - Discharge siphons water out of the trap, opening a path for sewer gas.
Question 6
A replacement window in a second-floor bedroom does not qualify for a grade-floor exception. Its listed frame size is 28 by 72 inches, but its actual unobstructed opening is 23 inches wide by 32 inches high. The opening's bottom is 39 inches above the interior floor, and the window opens without keys or tools. The applicable requirements are at least 5.7 square feet of net clear area, 20 inches clear width, 24 inches clear height, and a maximum 44-inch sill height. A 5.0-square-foot area exception applies only to grade-floor openings. What is the correct assessment of the available escape opening?
Show answer & explanation
Correct answer: C - About 5.11 square feet; insufficient for this second-floor bedroom.
Question 7
A South Carolina home was built in 1974, but its interior staircase was completely reconstructed in 2013. During an inspection in 2026, the inspector intends to identify a stair deficiency as a building-code violation. The code allegation must be based on:
Show answer & explanation
Correct answer: A - The applicable code in effect when the staircase was reconstructed in 2013.
Question 8
The middle portion of a concrete-block basement wall bows inward, with a long horizontal crack along a mortar joint. The wall is closer to plumb at its top and bottom, and exterior soil extends nearly to the top of the wall. This deformation pattern is most consistent with:
Show answer & explanation
Correct answer: D - Lateral loading of the foundation wall from retained soil or water
Question 9
Despite a dry attic and no reported leaks, an asphalt-shingle roof has widespread brittle splitting, curled edges, and areas of exposed asphalt. The buyer asks whether it has 'at least five good years left.' Which statement belongs in the roof assessment?
Show answer & explanation
Correct answer: C - The deterioration supports replacement planning; a precise remaining service life cannot be established.
Question 10
An exterior meter-main contains the dwelling's service disconnect and neutral-to-ground bond. A four-wire feeder supplies an indoor panel. In that indoor panel, a bonding screw connects the neutral bar to the metal cabinet; the equipment-grounding bar is also bonded to the cabinet. Which correction should an electrician make?
Show answer & explanation
Correct answer: D - Isolate the neutral bar from the cabinet while retaining the equipment-grounding bar's cabinet bond.
That's 10 of 1,030
The full bank has 1,020 more SC-HI questions with explanations.